Editorial
There is a debate over the two-point technique for fluoroscopic-guided endoscopic procedures, two-point technique (TPT)”, in urology as was mentioned in research by Wagmaister and his colleagues (1). They conducted a validation study by introducing a new technique to reduce radiation dose and fluoroscopic time during endoscopic urological procedures.
The TPT is explained in the article for Fluoroscopic-Guided Endoscopic Procedures, in which the fluoroscope image is shifted between caudal and cephalad points of the operative field. TPT technique could successfully shorten the mean fluoroscopy time from approximately 104 to 71 seconds and the mean radiation dose from around 20 mGy to 11 mGy and this is wrathful for not the only surgical team, but the patient as well.
It could be found from the text all adult males and females requiring ureteroscopy or any fluoroscopy-guided endoscopic urologic procedure except for percutaneous renal procedures are included in your study. It means that all of these procedures were done by fluoroscopic guidance. There was ureteroscopic stone treatment, ureteral or renal pelvis biopsy, endoscopic upper urinary tract tumor resection, diagnostic ureteroscopy, Double-J stent exchange, dilation of ureteral stricture, and endopyelotomy. It seems that Some of these procedures don’t need fluoroscopy. Fluoroscopy is indicated in some studies if balloon dilatation is used during ureteral dilatation for urethral stricture (2). But it doesn’t mention why radiation is used for double – j exchange. Are all of these 106 patients need radiation exposure?
When it comes to endourological procedures, we believe that we could use less radiation in our procedures. Diagnostic ureteroscopy could be finely done by the guidewire and with slimmer ureteroscopes. In cases with severe stricture, hydrophilic guidewires could help the urologist. And for the last solution, we can leave a double j stent for a few weeks for passive dilatation. This strategy could be safer for both surgeon and the patient. Considering the ALARA principle (as low as reasonably achievable), that radiation doses should be kept as low as reasonably achievable, social and economic factors are well-known to medical physicists. It is perhaps less well-known that the ALARA principle applies to medical exposures and other sources of radiation exposure (3).
Conclusions
Although this technique helps reduce radiation exposure to the urologist and surgical team, a urologist should try to use less radiation through fluoroscopy during routine urologic procedures. As we can see the urethral lumen clearly by Ureteroscope and endoscopic visions, we rarely use x-ray during our routine procedures in our center, except for percutaneous nephrolithotripsy.
Authors’ contributions
SMKA is mainly designed and suggests the manuscript's main idea; AFY wrote the manuscript, and SMKA edited it.
Acknowledgments
Special thanks to the Sina hospital, Tehran University of Medical Sciences, Tehran, Iran.
Conflict of interest
The authors declare that there is no conflict of interest.
Funding
The authors received no financial support for this research.
Ethical statements
Not applicable.
Data availability
Not applicable.
Abbreviations
ALARA As low as reasonably achievable
DJ Double-J
TPT Two-point technique